Select the appropriate procedure code based on the approach & device:

4A03 - Arterial

  • Open Approach

    Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

    • Flow
      • 4A03051 - Measurement of Arterial Flow, Peripheral, Open Approach
      • 4A03053 - Measurement of Arterial Flow, Pulmonary, Open Approach
      • 4A0305C - Measurement of Arterial Flow, Coronary, Open Approach
    • Pressure
      • 4A030B1 - Measurement of Arterial Pressure, Peripheral, Open Approach
      • 4A030B3 - Measurement of Arterial Pressure, Pulmonary, Open Approach
      • 4A030BC - Measurement of Arterial Pressure, Coronary, Open Approach
      • 4A030BF - Measurement of Arterial Pressure, Oth Thor, Open Approach
    • Sound
      • 4A030H1 - Measurement of Arterial Sound, Peripheral, Open Approach
    • Pulse
      • 4A030J1 - Measurement of Arterial Pulse, Peripheral, Open Approach
      • 4A030J3 - Measurement of Arterial Pulse, Pulmonary, Open Approach
      • 4A030JC - Measurement of Arterial Pulse, Coronary, Open Approach
    • Saturation
      • 4A030R1 - Measure of Arterial Saturation, Peripheral, Open Approach

  • Percutaneous Approach

    Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

    • Flow
      • 4A03351 - Measurement of Arterial Flow, Peripheral, Perc Approach
      • 4A03353 - Measurement of Arterial Flow, Pulmonary, Perc Approach
      • 4A0335C - Measurement of Arterial Flow, Coronary, Perc Approach
    • Pressure
      • 4A033B1 - Measurement of Arterial Pressure, Peripheral, Perc Approach
      • 4A033B3 - Measurement of Arterial Pressure, Pulmonary, Perc Approach
      • 4A033BC - Measurement of Arterial Pressure, Coronary, Perc Approach
      • 4A033BF - Measurement of Arterial Pressure, Oth Thor, Perc Approach
    • Sound
      • 4A033H1 - Measurement of Arterial Sound, Peripheral, Perc Approach
    • Pulse
      • 4A033J1 - Measurement of Arterial Pulse, Peripheral, Perc Approach
      • 4A033J3 - Measurement of Arterial Pulse, Pulmonary, Perc Approach
      • 4A033JC - Measurement of Arterial Pulse, Coronary, Perc Approach
    • Saturation
      • 4A033R1 - Measure of Arterial Saturation, Peripheral, Perc Approach

  • External Approach

    Procedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane

    • Flow
      • 4A03X51 - Measurement of Arterial Flow, Peripheral, External Approach
      • 4A03X5D - Measurement of Arterial Flow, Intracranial, Extern Approach
    • Pressure
      • 4A03XB1 - Measure of Arterial Pressure, Peripheral, Extern Approach
    • Sound
      • 4A03XH1 - Measurement of Arterial Sound, Peripheral, External Approach
    • Pulse
      • 4A03XJ1 - Measurement of Arterial Pulse, Peripheral, External Approach
    • Saturation
      • 4A03XR1 - Measure of Arterial Saturation, Peripheral, Extern Approach