ICD-10 Code A01.00
Typhoid fever, unspecified
ICD-10 Code A01.00 is used to diagnose typhoid fever, unspecified, which is a potentially life-threatening systemic infection caused by the bacterium Salmonella enterica serotype Typhi. This condition primarily spreads through the ingestion of food or water contaminated with infected human feces and remains a significant health concern in regions with inadequate sanitation and limited access to clean water. Clinically, patients present with prolonged high fever, fatigue, headache, abdominal pain, constipation or diarrhea, hepatosplenomegaly, and occasionally a transient macular rash known as rose spots. If left untreated, the infection can progress to severe systemic complications such as intestinal perforation, gastrointestinal hemorrhage, and altered mental status. Related diseases and conditions within the same clinical spectrum include paratyphoid fever, Salmonella gastroenteritis, severe sepsis secondary to enteric infection, and organ-specific typhoid manifestations such as typhoid meningitis, typhoid pneumonia, typhoid arthritis, and typhoid osteomyelitis.
A01.00 is a valid billable ICD-10 diagnosis code for Typhoid fever, unspecified. It is found in the 2027 version of the ICD-10 CM Index and can be used in all HIPAA-covered transactions from Oct 01, 2026 - Sep 30, 2027.
The use of ICD-10 code A01.00 can also apply to:
- Eberth's disease (typhoid fever)
- Typhoid (abortive) (ambulant) (any site) (clinical) (fever) (hemorrhagic) (infection) (intermittent) (malignant) (rheumatic) (Widal negative)
- Typhomania
- MDC 18 Infectious & Parasitic Diseases, Systemic or Unspecified Sites
Other Infectious and Parasitic Disease Diagnoses
ICD-10 code A01.00 is based on the following Tabular structure:
Chapter 1: Certain infectious and parasitic diseases- Section A00-A09: Intestinal infectious diseases
- Category A01: Typhoid and paratyphoid fevers
↑ Parent code:
A01.0 for Typhoid fever
Should you use A01.00 or A0100 (with or without decimal point) when submitting claims?
DO NOT include the decimal point when electronically filing claims as it may be rejected. Some clearinghouses may remove it for you
but to avoid having a rejected claim due to an invalid ICD-10 code, do not include the decimal point when submitting claims electronically.
This note further define, or give examples of, the content of the code or category.
List of terms is included under some codes. These terms are the conditions for which that code is to be used. The terms may be synonyms of the code title, or, in the case of “other specified” codes, the terms are a list of the various conditions assigned to that code. The inclusion terms are not necessarily exhaustive. Additional terms found only in the Alphabetic Index may also be assigned to a code.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.
A type 1 Excludes note is a pure excludes. It means 'NOT CODED HERE!' An Excludes1 note indicates that the code excluded should never be used at the same time as the code above the Excludes1 note. An Excludes1 is used when two conditions cannot occur together, such as a congenital form versus an acquired form of the same condition.
A type 2 Excludes note represents 'Not included here'. An Excludes2 note indicates that the condition excluded is not part of the condition it is excluded from but a patient may have both conditions at the same time. When an Excludes2 note appears under a code it is acceptable to use both the code and the excluded code together.
A “code also” note instructs that two codes may be required to fully describe a condition, but this note does not provide sequencing direction. The sequencing depends on the circumstances of the encounter.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.