ICD-10 Code D68.61
Antiphospholipid syndrome
D68.61 is the ICD-10-CM code used for diagnosing antiphospholipid syndrome, an autoimmune disorder characterized by an increased risk of blood clots and pregnancy-related complications. This condition occurs when the body produces autoantibodies, such as lupus anticoagulant, anticardiolipin antibodies, or anti-beta-2-glycoprotein I antibodies, that mistakenly target phospholipid-binding proteins and trigger abnormal coagulation. Clinical manifestations covered under this diagnosis include vascular thromboses like deep vein thrombosis, pulmonary embolism, arterial thrombosis leading to stroke or myocardial infarction, and cutaneous symptoms such as livedo reticularis. The code also applies to obstetric complications associated with the syndrome, including recurrent early miscarriages, unexplained fetal loss, severe preeclampsia, and placental insufficiency. Antiphospholipid syndrome can occur independently as a primary condition or secondary to other autoimmune diseases, most commonly systemic lupus erythematosus.
- Anticardiolipin syndrome
- Antiphospholipid antibody syndrome
D68.61 is a valid billable ICD-10 diagnosis code for Antiphospholipid syndrome. It is found in the 2027 version of the ICD-10 CM Index and can be used in all HIPAA-covered transactions from Oct 01, 2026 - Sep 30, 2027.
Check for any exclusions, inclusions or special notations associated with D68.61
D68.61 also applies to the following:
- Anticardiolipin syndrome
- Antiphospholipid antibody syndrome
The use of ICD-10 code D68.61 can also apply to:
- Anticardiolipin syndrome
- MDC 16 Diseases & Disorders of Blood, Blood Forming Organs, Immunologic Disorders
Reticuloendothelial and Immunity Disorders
ICD-10 code D68.61 is based on the following Tabular structure:
Chapter 3: Diseases of the blood and blood-forming organs and certain disorders involving the immune mechanism- Section D65-D69: Coagulation defects, purpura and other hemorrhagic conditions
- Category D68: Other coagulation defects
↑ Parent code:
D68.6 for Other thrombophilia
Should you use D68.61 or D6861 (with or without decimal point) when submitting claims?
DO NOT include the decimal point when electronically filing claims as it may be rejected. Some clearinghouses may remove it for you
but to avoid having a rejected claim due to an invalid ICD-10 code, do not include the decimal point when submitting claims electronically.
This note further define, or give examples of, the content of the code or category.
List of terms is included under some codes. These terms are the conditions for which that code is to be used. The terms may be synonyms of the code title, or, in the case of “other specified” codes, the terms are a list of the various conditions assigned to that code. The inclusion terms are not necessarily exhaustive. Additional terms found only in the Alphabetic Index may also be assigned to a code.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.
A type 1 Excludes note is a pure excludes. It means 'NOT CODED HERE!' An Excludes1 note indicates that the code excluded should never be used at the same time as the code above the Excludes1 note. An Excludes1 is used when two conditions cannot occur together, such as a congenital form versus an acquired form of the same condition.
A type 2 Excludes note represents 'Not included here'. An Excludes2 note indicates that the condition excluded is not part of the condition it is excluded from but a patient may have both conditions at the same time. When an Excludes2 note appears under a code it is acceptable to use both the code and the excluded code together.
A “code also” note instructs that two codes may be required to fully describe a condition, but this note does not provide sequencing direction. The sequencing depends on the circumstances of the encounter.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.