ICD-10 Code F06.1
Catatonic disorder due to known physiological condition
F06.1 is the ICD-10-CM code used to diagnose catatonic disorder due to a known physiological condition, which describes prominent psychomotor disturbances directly caused by an underlying medical, neurological, or systemic illness rather than a primary psychiatric disease. Clinicians apply this diagnosis when a patient presents with classic catatonic features, such as stupor, mutism, posturing, waxy flexibility, severe negativity, or non-purposeful psychomotor agitation, and medical workup confirms an organic etiology. Prompt recognition is critical because resolving the catatonia relies heavily on treating the underlying physiological driver alongside supportive psychopharmacological interventions, such as high-dose benzodiazepines. Diseases and conditions frequently associated with this diagnosis include autoimmune encephalopathies such as anti-NMDAR encephalitis, severe metabolic derangements like hepatic or renal encephalopathy, central nervous system infections, systemic lupus erythematosus, traumatic brain injury, cerebrovascular accidents, thyroid dysfunction, and neurodegenerative disorders.
- Catatonia associated with another mental disorder
- Catatonia NOS
F06.1 is a valid billable ICD-10 diagnosis code for Catatonic disorder due to known physiological condition. It is found in the 2027 version of the ICD-10 CM Index and can be used in all HIPAA-covered transactions from Oct 01, 2026 - Sep 30, 2027.
Check for any exclusions, inclusions or special notations associated with F06.1
F06.1 also applies to the following:
- Catatonia associated with another mental disorder
- Catatonia NOS
- MDC 19 Mental Diseases & Disorders
Organic Disturbances and Intellectual Disability- DRG 884 - ORGANIC DISTURBANCES AND INTELLECTUAL DISABILITY
ICD-10 code F06.1 is based on the following Tabular structure:
Chapter 5: Mental, Behavioral and Neurodevelopmental disorders- Section F01-F09: Mental disorders due to known physiological conditions
- Category F06: Other mental disorders due to known physiological condition
Should you use F06.1 or F061 (with or without decimal point) when submitting claims?
DO NOT include the decimal point when electronically filing claims as it may be rejected. Some clearinghouses may remove it for you
but to avoid having a rejected claim due to an invalid ICD-10 code, do not include the decimal point when submitting claims electronically.
This note further define, or give examples of, the content of the code or category.
List of terms is included under some codes. These terms are the conditions for which that code is to be used. The terms may be synonyms of the code title, or, in the case of “other specified” codes, the terms are a list of the various conditions assigned to that code. The inclusion terms are not necessarily exhaustive. Additional terms found only in the Alphabetic Index may also be assigned to a code.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.
A type 1 Excludes note is a pure excludes. It means 'NOT CODED HERE!' An Excludes1 note indicates that the code excluded should never be used at the same time as the code above the Excludes1 note. An Excludes1 is used when two conditions cannot occur together, such as a congenital form versus an acquired form of the same condition.
A type 2 Excludes note represents 'Not included here'. An Excludes2 note indicates that the condition excluded is not part of the condition it is excluded from but a patient may have both conditions at the same time. When an Excludes2 note appears under a code it is acceptable to use both the code and the excluded code together.
A “code also” note instructs that two codes may be required to fully describe a condition, but this note does not provide sequencing direction. The sequencing depends on the circumstances of the encounter.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.