ICD-10 Code F44.6
Conversion disorder with sensory symptom or deficit
F44.6 is the International Classification of Diseases, Tenth Revision code used to classify dissociative anesthesia and sensory loss, a distinct clinical presentation of conversion disorder or functional neurological symptom disorder. This condition involves an involuntary loss or alteration of sensory perception, such as tactile sensation, pain perception, vision, hearing, or olfaction, that cannot be attributed to any structural, neurological, or physiological medical pathology. The onset or exacerbation of these sensory deficits is frequently linked to acute emotional stress, psychological trauma, or intrapsychic conflict, representing a process where psychological distress unconsciously manifests as physical sensory deficits. Diagnostic evaluation requires a thorough neurological workup alongside a psychiatric assessment to confirm that the symptoms do not conform to known anatomical patterns, such as nerve dermatomes, and to rule out organic causes like cerebral vascular accidents, multiple sclerosis, or peripheral neuropathy. This code applies to various specific manifestations of non-organic sensory dysfunction, including psychogenic blindness or visual loss, psychogenic deafness, psychogenic loss of smell or taste, and dissociative cutaneous anesthesia where skin sensation is lost in non-anatomical distributions like glove-and-stocking patterns without underlying nerve damage. Related and overlapping conditions within the same diagnostic category include other conversion spectrum conditions such as dissociative motor disorders, dissociative convulsions or psychogenic non-epileptic seizures, and mixed dissociative disorders. Furthermore, clinicians often evaluate F44.6 alongside related psychiatric diagnoses that frequently present with somatic manifestations, including somatic symptom disorder, generalized anxiety disorder, major depressive disorder, and post-traumatic stress disorder.
- Conversion disorder with anesthesia or sensory loss
- Conversion disorder with special sensory symptoms
- Dissociative anesthesia and sensory loss
- Psychogenic deafness
F44.6 is a valid billable ICD-10 diagnosis code for Conversion disorder with sensory symptom or deficit. It is found in the 2027 version of the ICD-10 CM Index and can be used in all HIPAA-covered transactions from Oct 01, 2026 - Sep 30, 2027.
Check for any exclusions, inclusions or special notations associated with F44.6
F44.6 also applies to the following:
- Conversion disorder with anesthesia or sensory loss
- Conversion disorder with special sensory symptoms
- Dissociative anesthesia and sensory loss
- Psychogenic deafness
- MDC 19 Mental Diseases & Disorders
Acute Adjustment Reaction and Psychosocial Dysfunction- DRG 880 - ACUTE ADJUSTMENT REACTION AND PSYCHOSOCIAL DYSFUNCTION
ICD-10 code F44.6 is based on the following Tabular structure:
Chapter 5: Mental, Behavioral and Neurodevelopmental disorders- Section F40-F48: Anxiety, dissociative, stress-related, somatoform and other nonpsychotic mental disorders
- Category F44: Dissociative and conversion disorders
Should you use F44.6 or F446 (with or without decimal point) when submitting claims?
DO NOT include the decimal point when electronically filing claims as it may be rejected. Some clearinghouses may remove it for you
but to avoid having a rejected claim due to an invalid ICD-10 code, do not include the decimal point when submitting claims electronically.
This note further define, or give examples of, the content of the code or category.
List of terms is included under some codes. These terms are the conditions for which that code is to be used. The terms may be synonyms of the code title, or, in the case of “other specified” codes, the terms are a list of the various conditions assigned to that code. The inclusion terms are not necessarily exhaustive. Additional terms found only in the Alphabetic Index may also be assigned to a code.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.
A type 1 Excludes note is a pure excludes. It means 'NOT CODED HERE!' An Excludes1 note indicates that the code excluded should never be used at the same time as the code above the Excludes1 note. An Excludes1 is used when two conditions cannot occur together, such as a congenital form versus an acquired form of the same condition.
A type 2 Excludes note represents 'Not included here'. An Excludes2 note indicates that the condition excluded is not part of the condition it is excluded from but a patient may have both conditions at the same time. When an Excludes2 note appears under a code it is acceptable to use both the code and the excluded code together.
A “code also” note instructs that two codes may be required to fully describe a condition, but this note does not provide sequencing direction. The sequencing depends on the circumstances of the encounter.
Certain conditions have both an underlying etiology and multiple body system manifestations due to the underlying etiology. For such conditions, the ICD-10 CM has a coding convention that requires the underlying condition be sequenced first, if applicable, followed by the manifestation. Wherever such a combination exists, there is a “use additional code” note at the etiology code, and a “code first” note at the manifestation code. These instructional notes indicate the proper sequencing order of the codes, etiology followed by manifestation.