D
The Testis body part is identified by the character D
in the 4th position of the ICD-10-PCS procedure code.
It is contained within the Revision root operation of the Male Reproductive System body system
under the Medical and Surgical section. The 4the position refers to the body part or body region when applicable.
Section:
0
= Medical and Surgical
Body System:
V
= Male Reproductive System
Root Operation:
W
= Revision
Body Part:
M
- Epididymis and Spermatic CordS
- Penis4
- Prostate and Seminal Vesicles8
- Scrotum and Tunica VaginalisD
- TestisR
- Vas DeferensSelect the appropriate procedure code based on the approach & device:
0VWD
- Testis
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
0VWD00Z
- Revision of Drainage Device in Testis, Open Approach0VWD03Z
- Revision of Infusion Device in Testis, Open Approach0VWD07Z
- Revision of Autol Sub in Testis, Open Approach0VWD0JZ
- Revision of Synthetic Substitute in Testis, Open Approach0VWD0KZ
- Revision of Nonaut Sub in Testis, Open Approach0VWD0YZ
- Revision of Other Device in Testis, Open ApproachEntry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
0VWD30Z
- Revision of Drainage Device in Testis, Percutaneous Approach0VWD33Z
- Revision of Infusion Device in Testis, Percutaneous Approach0VWD37Z
- Revision of Autol Sub in Testis, Perc Approach0VWD3JZ
- Revision of Synthetic Substitute in Testis, Perc Approach0VWD3KZ
- Revision of Nonaut Sub in Testis, Perc Approach0VWD3YZ
- Revision of Other Device in Testis, Percutaneous ApproachEntry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
0VWD40Z
- Revision of Drainage Device in Testis, Perc Endo Approach0VWD43Z
- Revision of Infusion Device in Testis, Perc Endo Approach0VWD47Z
- Revision of Autol Sub in Testis, Perc Endo Approach0VWD4JZ
- Revision of Synth Sub in Testis, Perc Endo Approach0VWD4KZ
- Revision of Nonaut Sub in Testis, Perc Endo Approach0VWD4YZ
- Revision of Other Device in Testis, Perc Endo ApproachEntry of instrumentation through a natural or artificial external opening to reach the site of the procedure
0VWD70Z
- Revision of Drainage Device in Testis, Via Opening0VWD73Z
- Revision of Infusion Device in Testis, Via Opening0VWD77Z
- Revision of Autol Sub in Testis, Via Opening0VWD7JZ
- Revision of Synthetic Substitute in Testis, Via Opening0VWD7KZ
- Revision of Nonaut Sub in Testis, Via Opening0VWD7YZ
- Revision of Other Device in Testis, Via OpeningEntry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure
0VWD80Z
- Revision of Drainage Device in Testis, Endo0VWD83Z
- Revision of Infusion Device in Testis, Endo0VWD87Z
- Revision of Autologous Tissue Substitute in Testis, Endo0VWD8JZ
- Revision of Synthetic Substitute in Testis, Endo0VWD8KZ
- Revision of Nonautologous Tissue Substitute in Testis, Endo0VWD8YZ
- Revision of Other Device in Testis, EndoProcedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane
0VWDX0Z
- Revision of Drainage Device in Testis, External Approach0VWDX3Z
- Revision of Infusion Device in Testis, External Approach0VWDX7Z
- Revision of Autol Sub in Testis, Extern Approach0VWDXJZ
- Revision of Synthetic Substitute in Testis, Extern Approach0VWDXKZ
- Revision of Nonaut Sub in Testis, Extern Approach