2
The Cardiac body part is identified by the character 2
in the 4th position of the ICD-10-PCS procedure code.
It is contained within the Measurement root operation of the Physiological Systems body system
under the Measurement and Monitoring section. The 4the position refers to the body part or body region when applicable.
Section:
4
= Measurement and Monitoring
Body System:
A
= Physiological Systems
Root Operation:
0
= Measurement
Body Part:
3
- ArterialC
- Biliary2
- Cardiac0
- Central Nervous5
- CirculatoryB
- Gastrointestinal6
- LymphaticF
- MusculoskeletalZ
- None8
- Olfactory1
- Peripheral NervousH
- Products of Conception, CardiacJ
- Products of Conception, Nervous9
- RespiratoryD
- Urinary4
- Venous7
- VisualSelect the appropriate procedure code based on the approach & device:
4A02
- Cardiac
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
4A0204Z
- Measurement of Cardiac Electrical Activity, Open Approach4A0209Z
- Measurement of Cardiac Output, Open Approach4A020CZ
- Measurement of Cardiac Rate, Open Approach4A020FZ
- Measurement of Cardiac Rhythm, Open Approach4A020HZ
- Measurement of Cardiac Sound, Open Approach4A020PZ
- Measurement of Cardiac Action Currents, Open ApproachEntry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
4A0234Z
- Measurement of Cardiac Electrical Activity, Perc Approach4A0239Z
- Measurement of Cardiac Output, Percutaneous Approach4A023CZ
- Measurement of Cardiac Rate, Percutaneous Approach4A023FZ
- Measurement of Cardiac Rhythm, Percutaneous Approach4A023HZ
- Measurement of Cardiac Sound, Percutaneous Approach4A023PZ
- Measurement of Cardiac Action Currents, Perc ApproachEntry of instrumentation through a natural or artificial external opening to reach the site of the procedure
4A0274Z
- Measurement of Cardiac Electrical Activity, Via Opening4A0279Z
- Measurement of Cardiac Output, Via Opening4A027CZ
- Measurement of Cardiac Rate, Via Opening4A027FZ
- Measurement of Cardiac Rhythm, Via Opening4A027HZ
- Measurement of Cardiac Sound, Via Opening4A027PZ
- Measurement of Cardiac Action Currents, Via OpeningEntry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure
4A0284Z
- Measurement of Cardiac Electrical Activity, Endo4A0289Z
- Measurement of Cardiac Output, Endo4A028CZ
- Measurement of Cardiac Rate, Endo4A028FZ
- Measurement of Cardiac Rhythm, Endo4A028HZ
- Measurement of Cardiac Sound, Endo4A028PZ
- Measurement of Cardiac Action Currents, EndoProcedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane
4A02X9Z
- Measurement of Cardiac Output, External Approach4A02XCZ
- Measurement of Cardiac Rate, External Approach4A02XFZ
- Measurement of Cardiac Rhythm, External Approach4A02XHZ
- Measurement of Cardiac Sound, External Approach4A02XM4
- Measurement of Cardiac Total Activity, External Approach4A02XPZ
- Measurement of Cardiac Action Currents, External Approach